Optical Coherence Tomographs(OCT)
It is a non invasive imaging modality which uses light waves to takes optical cross sections of the light sensitive layer of the eye which is retina. Each of the ten distinctive layers of the retina can be visualized with high resolution, allowing detection and measurement of any abnormality in each of these layers. This provides useful information to diagnose several important retinal conditions such as diabetic retinopathy and Age related Macular degeneration (ARMD). It is also a very useful tool to monitor benefits of treatment in these diseases. The new feature of OCT angiography also provides valuable information on the health of various retinal vasculature without the need for invasive dye injection. OCT can also provide high resolution images of the optic disc and the anterior segment, thus becoming a valuable tool in diagnosing and monitoring glaucoma.

Auto Refractometer
The operator measure the refractive error and help in accurate prescription of glasses even in children and measure diameter of the cornea, pupil or hard contact lenses worn by the patient. The patient focuses on a color photo target and when measurement is taken the data displays instantly.

Lenstar
Lenstar is used for obtaining Ocular Measurement and performing calculations to assist in the determination of the appropriate power and type of IOL (Intra Ocular Lens) for implantation after removal of Cataract.

A-Scan
A-Scan is a routine type of diagnostic test used in ophthalmology. This equipment provides data on the length of the eye, which is a major determinant in common sight disorders. The most common use is to determine eye length for calculation of intraocular lens power.

Humphery Fields Analyser
It is the newest and most advanced visual field testing platform for glaucoma and optic nerve diseases. This equipment determines the stage of disease, rate of progression and a patient's risk of future vision loss by automatically summarizing all available visual field test results, by calculating each patient's rate of visual field deterioration. With this advanced perimeter, you can more closely monitor changes in the eye to prevent irreversible loss of vision for a disease that often has no warning signs.

Yag Laser
Yag laser equipment produces short-pulsed, high-energy light beams to cut, perforate, or fragment tissue useful to improve vision when posterior capsule thickens after surgery. The YAG laser is commonly used to vaporize a portion of the capsule, allowing light to pass through to the retina. The procedure is completely painless, takes only a few minutes, and is effective in eliminating the cloudy condition.

Fundus Camera & FFA
Fundus photography involves taking a picture of the light sensitive layer of the eye called the retina. The instrument consists of an intricate microscope attached to a flash enabled camera. The main structures visualized are the retina, optic disc and the macula and 60deg of the retinal periphery. It is a very useful tool to visualize and document findings in that portion of the eye which is not evident to the patient directly. It also allows monitoring the progression of the diagnosed eye conditions.

B-Scan With UBM
B-scan ultrasonography is an important adjuvant especially in opaque media for the clinical assessment of various ocular and orbital diseases. Can be used to rule out retinal, vitreous, and choroidal detachments, tumors, and other pathologies that affect the posterior segment of the eye. UBM is high resolution tool for anterior segment imaging. Indicated in opaque cornea, anterior segment trauma, hypotony, angle evaluation, IOL position.

Infinity Vision System
INFINITY VISION SYSTEM is high end Phaco Machine and is designed for smoother cutting of Cataract and excellent efficiency for Micro Incision Cataract Surgery.

Vitrectomy-Machine
The microincision vitrectomy system (MIVS) machine is used to remove the vitreous gel from the inside of the eye which gives the surgeon better access to the back of the eye(retina) Vitreous is a clear, jelly-like substance that fills the inside of the eye. The machine performs the basic functions of vitreous cutting with 23G/25G/27G cutters, irrigation, aspiration, and illumination. The basic components of the vitrectomy machine are viewing system, vitreous cutters, infusion system, and operating microscope. It is performed in conditions such as retinal detachment, tractional diabetic retinal detactment, macular holes, vitreous haemorrhage etc.

Photo Slit Lamp
Slit lamp biomicroscopy Instrument Manufacturers-TopCon. The console consists of a slit lamp biomicroscope equipped with a digital camera for capturing static and dynamic, single and multiple images of the ocular surface and anterior segment. The images are displayed and stored in the files. They can be visualized, stored, magnified and retrieved for further use. Uses:Documentation of ocular pathology with the help of clear digital photographs. Helps in counselling the patients with regards to pathology.

Green Laser Unit
This double-frequency Nd-YAG laser (532nm) is a gold-standard for treatment of many pathologies by Photocoagulation. LASER stands for Light Amplification by Stimulated Emission of Radiation. LASERs used in the OPD (Out-patient department) are mainly used for the management of retinal conditions. These are done usually to the areas of ischemia in retina especially when abnormal new vessels are formed or to weak areas in retina (holes, tears). Mode od delivery is through a Slit-lamp, through the Laser Indirect Ophthalmoscope (LIO).

Pachymetry
Ultrasound Pachymetry Instrument: Ophthalmic Ultrasound Scanner. Manufacturers:Appasamy Associates. It is used for corneal thickness measurement by Immersion /contact method within a range of 200 to 1000 microns with an accuracy in the range of +/_5 microns. Probe frequency 10 MHz Other uses:Measurement of axial length,anterior chamber depth, Lens thickness.

Non-Contact Tonometer
A tonometer is a diagnostic tool used by eye care professionals to measure the intraocular pressure (IOP) inside a patient's eyes. A patient's IOP can help an ophthalmologist or optometrist determine a patient's risk for developing glaucoma — a disease that damages the optic nerve of the eye, usually resulting in vision loss or even blindness. A non-contact tonometer uses a small puff of air (which is why it's many times referred to as the "puff test") to measure an eye's pressure. Known as pneumotonometry, the air puff flattens the patient's cornea in a non-invasive way, meaning eyes do not need to be numbed prior to the test.

Green Laser
Green Laser (Light Amplification by Stimulated Emission of Radiation) Lasers are distinguished from other light sources by their coherence. They are usually expressed as a narrow beam, which is diffraction limited, allowing the beam to be focused to very tiny spots, achieving a very high irradiance at the desired spot. They are classified based on their wavelength. Laser have a lot of applications in ophthalmology. They are used to treat retinal conditions like Diabetic macular edema, proliferative diabetic retinopathy, lattice degenerations and atrophic holes in the retina, central serous retinopathy among many others. Lasers also play an important role in treating angle closure glaucoma and in treating posterior capsular pacification that develops after cataract surgery.

Operating Microscope
We have four functional and state of the art operating microscopes. Leica microscope systems – Premium optics and illumination, user comfort friendly, allows for imaging and 3D/2D display and documentation. TOPCON OMS-800 with continuous co-axial zoom for user comfort and surgical precision. Moller wedel –Posterior segment surgeries performed with precision with BIOM and digital camera for surgical documentation. All the operating microscopes facilitate better detail recognition, added patient safety and fatigue free running for the surgeon

Alcon Constellation for Retinal Surgeries
This is a highly advanced system powering complicated and delicate vitreo-retinal surgeries. It has a user friendly interface with an effortless voice confirmed settings and a multifunctional foot switch control. Intraocular pressure (IOP) control is a feature that sets the Constellation apart from other vitrectomy machines. It allows the surgeons to keep IOP within 2 mm Hg of a preset level. This, combined with valued trocars, becomes a controlled, predictable system. It maintains a stable eye pressure, an important prerequisite in surgeries for diabetic retinopathy. Another key advantage of using the Constellation is the dual pneumatic vitreous cutter, which relies on independent airflow to drive closing and opening of the cutter itself. Improved design includes optimized port location placed closer to the tip, allowing improved dissection of preretinal membranes. The Constellation uses a xenon light source that has a radio frequency identification (RFID) probe that automatically regulates light intensity based on the probe gauge size, thus minimizing the likelihood of inadvertent light toxicity. The constellation is compact and efficient, providing an optimum platform for a vitreo-retinal surgeon.

Corneal Topography
Corneal topography is a computer assisted diagnostic tool that creates a three-dimensional map of the surface curvature of the cornea. The corneal topography equipment consists of a computer linked to a lighted bowl that contains a pattern of rings. During a diagnostic test, the patient sits in front of the bowl with his or her head pressed against a bar while a series of data points are generated. This helps your eye care professional to diagnose conditions such as Various corneal diseases, Corneal deformities, Irregular astigmatism, Planning refractive surgery such as Lasik / ICL. Once diagnosed an appropriate treatment plan will be suggested by your eye doctor

Slit Lamp with Applanation Tonometry
Our Out Patient services are fully equipped with the latest technology for evaluation of the eye and treatment of disease. We have multiple ophthalmic units with slit lamps for detailed evaluation of anterior segment- cornea, lens, anterior vitreous and slit lamp biomicroscopy of post segment with the help of 90 or 78 dioptre lens. Minor procedures like foreign body removal are done with the slit lamp in the Out Patient Department. Tension applanation, the gold standard to measure the introcular pressure of the eye is also routinely performed and all our slit lamps are equipped with applanation prism heads and well calibrated units. We also take the maximum precautions for hygienic care of our patients in the pandemic era especially during slit lamp evalution or intraocular pressure measurement.

Phacoemulsification Machine
We have two state of the art Phaco systems.
1. Alcon infiniti phaco systems: It is an advanced phaco machine with venture pump and a widi range of innovative surgical options, with unique ozie Torsional handpiece for surgical precision and customization.
2. Amo sovereign compact phaco systems: Technically advanced phaco system with venture pump and automatic vitrectomy settings. It also has the innovative whitistar technology and ICE technology